Presentation |
Scalable power, runtime & distribution in a high-density, single-frame design. This high-efficiency 3-phase UPS scales as your data center grows up to 48kW/48kVA. Suitable for small & medium data center applications.
|
|
---|---|---|
Lead time |
Usually Ships within 2 Weeks
|
provided equipment |
Network management card
Start-up service |
|
---|---|---|
product web sub-family |
Symmetra PX 48kW
|
|
bypass wiring configuration |
5 wire (3P + N + E)
|
|
bypass voltage tolerance |
+/- 10 % settable from +/- 4/6/8 and 10 %
|
|
max bypass input current |
80 A
|
|
bypass current protection |
80 A
|
|
performance multiplier |
0.350208
|
|
Number of tare power |
490 W
|
|
Number of power module free slots |
0
|
|
Number of power module filled slots |
3
|
|
redundant |
Yes
|
|
size UPS version |
Internetworking
Server Telecom |
|
UPS size |
L
|
|
value multiplier |
0.81
|
number of rack unit |
42U
|
|
---|---|---|
colour |
Black
|
|
depth |
107 cm
|
|
height |
199.1 cm
|
|
mounting location |
Front
|
|
mounting preference |
No preference
|
|
net weight |
796 kg
|
|
mounting mode |
Not rack-mountable
|
|
two post mountable |
0
|
|
USB compatible |
No
|
|
width |
60 cm
|
network frequency |
40…70 Hz
|
|
---|---|---|
number of input connectors |
1 hard wire 5-wire (3P + N + E)
|
|
input voltage limits |
340…477 V
|
|
Input voltage |
380 V
400 V 415 V |
|
maximum input current |
98 A
|
|
switching current capacity |
100 A
|
|
max short time withstand current |
30 kA
|
|
input harmonic distortion |
Less than 5 % for full load
|
|
input protection type |
GL fuse
|
|
input voltage |
400 V 3 phases
|
|
load power factor |
0.5 leading to 0.5 lagging
|
|
cos phi |
0.99
|
rated power in W |
48000 W
|
|
---|---|---|
Maximum configurable power in W |
48000 W
|
|
harmonic distortion |
Less than 2 %
|
|
output frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
|
Output voltage |
380 V
400 V 415 V |
|
UPS type |
Double conversion online
|
|
Wave type |
Sine wave
|
|
output voltage tolerance |
+/- 1% static and +/- 5% at 100% load step
|
|
output harmonic distortion |
< 2% for 0 to 100% linear load and < 6% for full non-linear load
|
|
output overload operation |
10 minutes at 125% and 60 seconds at 150%
|
|
required output current protection |
100 A
|
|
bypass type |
Built-in static bypass
|
|
curve equation |
Efficiency
|
|
curve fixed loss |
0.0105
|
|
curve load maximum |
100 %
|
|
curve load minimum |
2 %
|
|
curve proportional loss |
0.0113
|
|
curve square loss |
0.0314
|
|
curve X-axis maximum |
100 %
|
|
curve test cond ID |
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
|
|
curve X-axis minimum |
0 %
|
|
curve X-axis title |
Load
|
|
curve X-axis units |
Percentage
|
|
curve Y-axis maximum |
100 %
|
|
curve Y-axis minimum |
50 %
|
|
curve Y-axis title |
Efficiency
|
|
curve Y-axis units |
Percentage
|
|
efficiency |
94 % (in battery operation)
|
|
graph display |
1
|
|
output voltage |
230 V
400 V 3 phases |
|
Maximum configurable power in VA |
48000 VA
|
|
rated power in VA |
48000 VA
|
product certifications |
EUROBAT
|
|
---|---|---|
standards |
EN 50091-1
EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 ISO 14001 ISO 9001 VFI-SS-111 |
ambient air temperature for operation |
0…40 °C
|
|
---|---|---|
relative humidity |
0…95 %
|
|
operating altitude |
0…3333 ft
|
|
ambient air temperature for storage |
-15…40 °C
|
|
storage Relative Humidity |
0…95 %
|
|
storage altitude |
0.00…15240.00 m
|
|
acoustic level |
61 dBA
|
|
heat dissipation |
7719 Btu/h
|
|
show note OP temperature |
No
|
|
NEMA degree of protection |
NEMA 1
|
battery type |
VRLA
|
|
---|---|---|
number of battery filled slots |
4
|
|
number of battery free slots |
0
|
|
Battery recharge time |
3 h
|
|
number of battery replacement quantity |
4
|
|
additional information |
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
|
|
liquid value |
0
|
|
battery voltage |
+/- 192 V (split battery referenced to neutral)
|
|
discharge battery voltage |
+/- 154 V
|
|
overcurrent protection |
1008 A
|
|
maximum short-circuit current |
4 kA
|
|
max current discharge |
165 A
|
|
battery overload operation |
10 minutes at 125% and 60 seconds at 150%
|
|
battery curve |
P
|
|
battery charger power |
4593 W rated
|
|
battery design life |
5…8 year(s)
|
|
Battery power in VAH |
13824 VAh runtime
|
|
battery option |
SYCFXR48-9 1 44928 VAh
SYCFXR48-9 2 76032 VAh SYCFXR48-9 3 107136 VAh SYCFXR48-9 4 138240 VAh |
|
extended runtime |
1
|
free slots |
2
|
|
---|---|---|
preinstalled device |
Network management card with CAN
|
|
control panel |
Multifunction LCD status and control console
|
|
alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays
|
|
Emergency power off |
Yes
|
Package 1 Weight |
858 kg
|
|
---|---|---|
Package 1 Height |
214 cm
|
|
Package 1 width |
84.8 cm
|
|
Package 1 Length |
121 cm
|
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
---|---|---|
Optimized Energy Efficiency |
Energy efficient product
|
Warranty |
1 year on-site repair or replace with factory authorized Start-Up
|
---|